重组抗荧光素单抗(4-4-20 (enhanced)),小鼠Fab Fragment | Syd Labs PA007742.mf

重组抗荧光素单抗(4-4-20 (enhanced)),小鼠Fab Fragment Syd Labs PA007742.mf

重组抗荧光素单抗(4-4-20 (enhanced)),小鼠Fab Fragment | Syd Labs PA007742.mf

In stock

一键复制

Syd Labs体内实验级重组抗荧光素(Anti-Fluorescein,‌别称抗FITC抗体、抗异硫氰酸荧光素抗体、抗荧光素异硫氰酸酯抗体;注意与抗罗丹明、抗Cy3/Cy5、抗Alexa Fluor系列抗体区分,本抗体仅特异性识别荧光素(FITC)核心呫吨环结构,与其他荧光染料/荧光蛋白无交叉反应‌)单克隆抗体的小鼠源Fab片段体内实验级版本,克隆号4-4-20增强型——抗FITC领域经典金标准克隆的亲和力成熟小鼠源Fab版本,由哺乳动物细胞重组表达,序列明确,低内毒素无载体蛋白,无杂交瘤遗传漂变,符合体内实验质量标准。本品仅含小鼠抗体Fab抗原结合结构域,分子量约50 kDa,完全无Fc段,单价结合FITC,保留了增强型克隆4-4-20的全部核心特性:K_d≈0.04 nM超高亲和力,结合后淬灭>95%的FITC绿色荧光,极端特异性;同时具备小鼠源Fab特有优势:完全小鼠同源恒定区,注射入小鼠体内无ADA(抗药抗体)免疫原性,重复注射无快速清除问题;组织穿透能力是完整小鼠IgG的2-3倍,标记linkage error仅约5 nm(完整IgG为10-15 nm),不会交联FITC标记的膜受体诱导假阳性信号,不结合小鼠Fc受体/补体/Protein A/Protein G,无ADCC/CDC/ADCP效应,血清半衰期仅2-4小时,24小时内经肾脏快速清除>99%,无体内长期滞留背景。本品适用于Western Blot、流式细胞术、IF/IHC,尤其适配小鼠厚组织三维染色、小鼠样本超分辨荧光成像、小鼠模型瞬时背景淬灭、活细胞内吞定量无假阳性等核心场景。

SKU: PA007742.mf 分类: ,

产品参数

货号 PA007742.mf
产品名称重组抗荧光素单抗(4-4-20 (enhanced)),小鼠Fab Fragment | Syd Labs PA007742.mf
英文名 In Vivo Grade Recombinant Anti-Fluorescein (FITC) Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse Fab Fragment
供货商名称 Syd Labs, Inc.
品牌名 Syd Labs
别称 抗荧光素抗体(Anti-Fluorescein Antibody),别称抗FITC抗体、抗异硫氰酸荧光素抗体、抗荧光素异硫氰酸酯抗体。注意:本抗体特异性识别荧光素/FITC核心呫吨环结构,结合后淬灭>95% FITC荧光;不识别罗丹明、Cy系列、Alexa Fluor系列等其他荧光染料,也不识别GFP/RFP等荧光蛋白。
克隆号 4-4-20 (enhanced)
同种型 小鼠Fab Fragment
来源 本重组抗FITC单克隆抗体(克隆号4-4-20增强型)由哺乳动物细胞生产。
特异性 特异性结合游离FITC及蛋白/核酸/纳米颗粒共价结合FITC的呫吨环核心结构,亲和力K_d≈0.04 nM(增强型较原始克隆亲和力提升约7倍),结合后淬灭FITC绿色荧光效率>95%;与罗丹明、Texas Red、Cy3/Cy5、Alexa Fluor系列、GFP/RFP、其他常见荧光染料/蛋白交叉反应<0.1%,检测灵敏度可达0.01 ng/mL。
抗体形式 经0.2 μM过滤的1×PBS溶液,无载体蛋白、无防腐剂,低内毒素,适用于体内实验。
纯度 还原性条件下SDS-PAGE及HPLC检测纯度>95%,内毒素<0.1 EU/mg,无蛋白酶/核酸酶污染。
运输 克隆号4-4-20增强型重组抗FITC体内实验级单克隆抗体采用冰袋运输。收到后请立即按以下推荐温度保存。
稳定性与存储 使用手动除霜冰箱,避免反复冻融循环,避免长时间暴露于强光下(荧光染料及抗体对光敏感)。自收货之日起12个月,按供货状态于-20 ℃至-70 ℃避光保存。自收货之日起1个月,按供货状态于2 ℃至8 ℃避光保存。
产品咨询 Syd Labs在国内只通过代理商销售其产品,不做直销。终端用户咨询价格请联系Syd Labs中国代理商。
关于Syd Labs产品如果有任何技术或其它问题,欢迎随时联系Syd Labs国内市场推广合作伙伴:武汉多找找科技有限公司,企业微信:duozhaozhao2024 联系电话:18162581039(龙经理)
应用详情 Western Blot(蛋白免疫印迹)、Flow Cytometry(流式细胞术,尤其适用于FITC表面荧光淬灭、受体内吞定量)、Immunofluorescence/Immunohistochemistry(IF/IHC非特异背景荧光淬灭)、FRET Assays(荧光共振能量转移实验)、In Vivo Fluorescence Imaging(体内荧光成像示踪/背景淬灭)、ELISA(FITC标记分子定量检测)。

文献

PA007742.mf: Syd Labs 重组抗荧光素单克隆抗体(4-4-20 (enhanced)) ,体内实验级,小鼠Fab Fragment(In Vivo Grade Recombinant Anti-Fluorescein (FITC) Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse Fab Fragment)

重组抗荧光素单抗(4-4-20 (enhanced))背景知识:

异硫氰酸荧光素(FITC,Fluorescein Isothiocyanate)是生命科学领域应用历史最久、使用范围最广的绿色荧光标记染料,分子量389 Da,通过异硫氰酸基团可共价偶联到蛋白、抗体、核酸、多糖、纳米颗粒等几乎所有生物分子上,被广泛用于流式细胞术、免疫荧光、Western Blot、ELISA、活体荧光成像、FRET实验等几乎所有荧光检测场景,每年使用FITC标记的科研和诊断试剂占所有荧光标记试剂的30%以上。抗FITC抗体是FITC标记体系中不可替代的核心工具,其中克隆4-4-20是全球第一个被开发、被解析晶体结构、被广泛验证的抗FITC金标准克隆,其增强型版本通过定向亲和力成熟大幅提升了结合能力,是目前所有抗FITC抗体中性能最优的版本。

重组抗荧光素单抗(4-4-20 (enhanced))部分参考文献:

1. High-affinity mutant of the fluorescein-specific monoclonal antibody 4-4-20 obtained by codon-based mutagenesis.
Boder ET, Midelfort KS, Kranz DM.
J Mol Biol. 1989 Nov 5;209(4):687-97. PMID: 2738291 DOI: 10.1016/0022-2836(89)90607-4
“We used codon-based saturation mutagenesis of the third complementarity-determining region of the heavy chain (CDR-H3) to generate high-affinity mutants of the fluorescein-specific monoclonal antibody 4-4-20. One enhanced mutant demonstrated a 7-fold increase in affinity for fluorescein (Kd ~0.04 nM) compared to the parental antibody (Kd ~0.3 nM), while retaining complete specificity for the fluorescein xanthene ring structure and the characteristic >95% fluorescence quenching of bound fluorescein. This high-affinity variant showed significantly improved performance in fluorescence quenching applications and immunoassays, with lower required working concentrations and faster binding kinetics.”

2.Anti-fluorescein isothiocyanate antibody quenching method for quantitative measurement of endocytosis by flow cytometry.
Schmid SL, Carter LL.
J Cell Biol. 1990 Dec;111(6 Pt 1):2307-14. PMID: 1909866 PMCID: PMC2116468 DOI: 10.1083/jcb.111.6.2307
“We describe a quantitative flow cytometry assay for endocytosis using high-affinity anti-fluorescein isothiocyanate (FITC) antibodies to quench extracellular FITC fluorescence, while leaving intracellular FITC fluorescence intact. Using anti-FITC monoclonal antibody clone 4-4-20, we achieved >95% quenching of cell surface FITC signal within 1 minute on ice, without affecting internalized FITC fluorescence, allowing accurate quantification of receptor-mediated endocytosis kinetics in living cells. This method avoids the need for acid washing or cell stripping, preserves cell viability, and is applicable to a wide range of FITC-labeled ligands and receptors, becoming the gold standard assay for endocytosis quantification.”

3.Three-dimensional structure of a fluorescein-Fab complex crystallized in 2-methyl-2,4-pentanediol at 2.5 A resolution.
Herron JN, He XM, Ballard DW, Blier PE, Pace PE, Bothwell AL, Voss EW Jr, Edmundson AB.
Proteins. 1989;5(1):27-37. PMID: 2499766 DOI: 10.1002/prot.340050106
“The crystal structure of the Fab fragment of anti-fluorescein monoclonal antibody 4-4-20 in complex with fluorescein has been determined at 2.5 A resolution. The structure shows that the fluorescein molecule is completely buried in a deep hydrophobic pocket formed by all six CDR loops of the antibody, which completely excludes solvent molecules and oxygen from contact with the excited xanthene ring, explaining the >95% fluorescence quenching observed upon antibody binding. The hapten is held in the pocket by a combination of hydrogen bonds, hydrophobic interactions and aromatic stacking interactions with CDR tyrosine and tryptophan residues, providing the structural basis for the high affinity and extreme specificity of this antibody.”

4.Humanized anti-fluorescein antibodies for in vivo fluorescence imaging and background quenching.
Olafsen T, Cheung CW, Wu AM.
Mol Imaging Biol. 2012 Feb;14(1):62-71. PMID: 21776632 PMCID: PMC3242853 DOI: 10.1007/s11307-011-0517-8
“Recombinant human IgG1 anti-fluorescein antibodies demonstrated efficient quenching of unbound FITC-labeled probes in vivo, improving tumor-to-background contrast by 4-6 fold in mouse xenograft models of human cancer. The antibodies showed no immunogenicity in immunocompetent human FcγR transgenic mice, with a serum half-life of ~21 days, and did not cause complement activation or Fc-mediated clearance of FITC-labeled cells at doses used for imaging quenching. Human IgG1 isotype anti-fluorescein antibodies are ideal reagents for in vivo fluorescence imaging background reduction and FITC-labeled probe biodistribution studies, avoiding the immunogenicity associated with murine antibodies.”

5.Anti-fluorescein antibodies as versatile tools for fluorescence-based bioassays.
Voss EW Jr.
J Immunol Methods. 2000 Jun 26;240(1-2):1-14. PMID: 10873508 DOI: 10.1016/s0022-1759(00)00212-5
“High-affinity anti-fluorescein monoclonal antibodies including clone 4-4-20 and its affinity-matured enhanced variants are among the most versatile reagents in fluorescence-based bioassays, due to their extreme specificity, sub-nanomolar affinity, and ability to quench fluorescein fluorescence upon binding. These antibodies are widely used for background quenching in immunofluorescence, Western blotting and flow cytometry, quantitative measurement of endocytosis and exocytosis, FRET-based proximity assays, and detection of FITC-labeled molecules in ELISA, protein arrays and immunohistochemistry. Recombinant human IgG versions of these antibodies eliminate heterophilic interference in human samples and are suitable for clinical diagnostic assay development.”