重组抗荧光素单抗(4-4-20 (enhanced)),小鼠F(ab) Kappa | Syd Labs PA007702.mf

重组抗荧光素单抗(4-4-20 (enhanced)),小鼠F(ab) Kappa Syd Labs PA007702.mf

重组抗荧光素单抗(4-4-20 (enhanced)),小鼠F(ab) Kappa | Syd Labs PA007702.mf

In stock

一键复制

Syd Labs体内实验级重组抗荧光素(Anti-Fluorescein / Anti-FITC)单克隆抗体的‌小鼠源F(ab)单价片段(Mouse F(ab) Kappa)‌,克隆号 4-4-20(enhanced,亲和力增强版),由哺乳动物细胞重组表达(重链仅含小鼠源VH-CH1即Fd段+完整小鼠Kappa轻链,不含铰链区、CH2、CH3结构域),序列明确、无酶切异质性,特异性识别荧光素(Fluorescein/FITC/FAM)核心呫吨环结构,对游离荧光素及FITC-蛋白/核酸/葡聚糖偶联物具有亚纳摩尔级高亲和力(K_d ~ 10⁻¹⁰ M)。小鼠F(ab)片段完全去除了完整小鼠IgG的Fc段,兼具以下核心特性:①‌完全消除小鼠Fc受体非特异结合‌——不结合任何小鼠FcγR(FcγRI/CD64、FcγRIIb/CD32b、FcγRIII/CD16、FcγRIV)和C1q,检测小鼠脾细胞、骨髓、肿瘤消化物、炎症组织等FcγR高表达样本时,彻底消除Fc段介导的非特异背景,‌无需额外添加Fc block(抗CD16/32,2.4G2)封闭试剂‌,实验流程更简单、信噪比更高;②‌无效应功能‌——完全无ADCC/CDC/ADCP活性,不会在小鼠血清补体或效应细胞存在时引发非特异杀伤;③‌分子量小(约50 kDa)‌——仅为完整小鼠IgG(约150 kDa)的1/3,组织穿透能力强,小鼠石蜡/冰冻切片、三维类器官、全组织免疫荧光深层染色更均匀;④‌单价结合‌——每个F(ab)分子仅含一个抗原结合位点,不会交联细胞表面受体导致非特异受体内吞或激活信号,适合纯阻断/受体内化实验;⑤‌抗鼠二抗完全兼容‌——小鼠源恒定区可直接用商品化抗小鼠Kappa轻链、抗小鼠Fab特异性二抗(HRP/AP/荧光/生物素)检测,无需特殊抗人二抗,与现有小鼠免疫学检测体系100%适配;⑥‌不结合Protein A/G‌——需用抗小鼠Kappa轻链、抗小鼠Fab或抗原亲和层析纯化。荧光素(Fluorescein)又称 ‌FITC(异硫氰酸荧光素)、FAM(6-羧基荧光素)、Resorcinolphthalein、Uranine(荧光素钠)、C.I. 45350‌,是呫吨类绿色荧光染料(Ex≈494 nm/Em≈521 nm)。小鼠F(ab)版本特别适用于:①小鼠免疫细胞样本流式细胞术低背景检测(核心用途,无需Fc block);②小鼠组织IHC/IF深层染色;③小鼠细胞受体纯阻断/配体内化实验;④侧向流免疫层析金标/荧光微球偶联;⑤双特异性抗体鼠源Fab模块构建;⑥Western Blot/ELISA常规检测FITC标记分子。本品经抗小鼠Kappa亲和纯化,还原性SDS-PAGE及HPLC检测纯度>95%,0.2 μM过滤于1×PBS溶液,适用于流式、WB、ELISA、IHC/IF、侧向流检测及受体功能实验。

SKU: PA007702.mf 分类: ,

产品参数

货号 PA007702.mf
产品名称重组抗荧光素单抗(4-4-20 (enhanced)),小鼠F(ab) Kappa | Syd Labs PA007702.mf
英文名 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse F(ab) Kappa
供货商名称 Syd Labs, Inc.
品牌名 Syd Labs
别称 Fluorescein、FITC(Fluorescein isothiocyanate / 异硫氰酸荧光素 / 荧光素异硫氰酸酯)、FAM(6-Carboxyfluorescein / 6-羧基荧光素)、Fluorescein isomer I、Resorcinolphthalein、Uranine(荧光素钠)、C.I. 45350、D&C Yellow No.7
克隆号 4-4-20 (enhanced)
同种型 小鼠F(ab) Kappa
特异性 特异性结合荧光素(Fluorescein/FITC/FAM)核心呫吨环结构,对游离荧光素及 FITC-蛋白/抗体/葡聚糖/核酸偶联物均有高亲和力
抗体形式 0.2 μM 过滤的 1× PBS 溶液
纯度 还原性条件下 SDS-PAGE 及 HPLC 检测>95%
运输 采用冰袋运输;收到后请立即按下方推荐温度保存
稳定性与存储 使用手动除霜冰箱,避免反复冻融;自收货之日起12个月,按供货状态于−20 ℃至−70 ℃保存;自收货之日起1个月,按供货状态于2 ℃至8 ℃保存
产品咨询 Syd Labs在国内只通过代理商销售其产品,不做直销。终端用户咨询价格请联系Syd Labs中国代理商。
关于Syd Labs产品如果有任何技术或其它问题,欢迎随时联系Syd Labs国内市场推广合作伙伴:武汉多找找科技有限公司,企业微信:duozhaozhao2024 联系电话:18162581039(龙经理)
应用详情 Flow Cytometry(流式细胞术,‌小鼠免疫细胞检测无需额外Fc block,背景极低‌)、Western Blot(抗小鼠Kappa-HRP二抗检测)、ELISA;可用于 IHC/IF免疫组化/免疫荧光(小鼠深层组织穿透染色)、侧向流免疫层析试纸(LFT/LFD,金标/荧光微球偶联空间位阻小、非特异吸附低)、小鼠细胞受体纯阻断/配体内化实验(无交联无杀伤)、双特异性抗体鼠源Fab模块构建、FITC标记分子体外检测

文献

PA007702.mf: Syd Labs 重组抗荧光素单克隆抗体(克隆号4-4-20 (enhanced)) ,小鼠F(ab) Kappa(Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse F(ab) Kappa)

重组抗荧光素单抗(4-4-20 (enhanced))背景知识:

我们的重组抗荧光素抗体(克隆号 4-4-20 增强型)为序列明确、哺乳动物细胞表达的抗 FITC 单克隆抗体,可特异性识别结合在蛋白、多肽、核酸或固相基质上的荧光素母核结构。该重组抗荧光素半抗原抗体稳定性高、性能可靠,是识别荧光素标记靶标、在各类常规体外免疫检测中放大信号的关键二步检测试剂,可彻底规避杂交瘤细胞株遗传漂移带来的风险。

相较于传统生物素 – 链霉亲和素体系,荧光素 / 抗荧光素检测体系具备突出优势:生物素广泛存在于多种哺乳动物组织及细胞裂解液中,因此基于生物素的检测往往背景偏高、易出现假阳性;而生物样本中天然不含荧光素,使用这款重组抗 FITC 单克隆抗体能够完全消除内源背景干扰。因此,该抗荧光素半抗原抗体非常适合用于复杂样本的体外诊断、ELISA 以及高通量筛选平台,可获得低背景、高准确度的实验数据。

我们可针对 4-4-20 增强型骨架提供全套抗体定制改造与规模化生产服务,面向诊断试剂盒研发企业及科研实验室。可提供的定制类型包括:
亚型转换与 Fc 改造:多种重链 / 轻链亚型以及改造型 Fc 变体(如效应沉默 LALAPG 突变体);
亲和标签:可重组添加 Avi 标签、His 标签或 DYKDDDDK(FLAG)标签,适配特定实验取向;
标记偶联:生物素化版本,也可直接偶联多种荧光基团、染料以及酶(辣根过氧化物酶 HRP、碱性磷酸酶 AP)。

重组抗荧光素单抗(4-4-20 (enhanced))部分参考文献:

1. CRISPR/Cas12a and fork-shaped probe enhance LAMP-LFT integration for equipment-free detection of Listeria monocytogenes.
Safenkova IV, et al.
Food Res Int. 2026 Apr;230:118592. PMID: 41794473 DOI: 10.1016/j.foodres.2026.118592
“An isothermal amplification assay integrated with lateral flow test (LFT) was developed for equipment-free detection of Listeria monocytogenes. In both LAMP-LFT and LAMP-CRISPR/Cas12a-LFT formats, fluorescein- and biotin-labeled amplicons were detected using a common conjugate of gold nanoparticles and anti-fluorescein (anti-FAM) antibodies, with a cleaved fork-shaped multi-fluorescein probe enabling visual readout on strips coated with anti-FAM capture antibody. The optimized assay achieved a single-cell detection limit (0.2 cells/reaction in buffer, 1 cell/reaction in spiked milk) within 80 min.”

2.A Versatile Cytochemical Labeling Technique as a Forensic Decision-Support Tool for In Situ Detection of Cell-Derived Markers in Invisible Biological Traces.
Bastat M, et al.
Anal Chem. 2025 Oct;97(41):22497–22507. PMID: 41057037 DOI: 10.1021/acs.analchem.5c02284
“A dual chromogenic and fluorescent in situ cytochemistry tool was developed to highlight invisible touch-DNA traces (e.g., fingermark corneocytes) on crime-scene surfaces. Chromogenic labeling of mannose residues and keratin 10 allowed visualization of as few as 100 shed cells, while a combination of FITC-conjugated primary probes and an HRP-conjugated anti-FITC antibody enabled simultaneous chromogenic and fluorescent detection across light and opaque substrates (ceramic, metal), supporting on-field sampling decisions prior to DNA extraction.”

3.Development of Reverse Transcriptase Recombinase Polymerase Amplification Combined with Lateral Flow Dipstick for Rapid Detection of Tilapia Lake Virus (TiLV): Pilot Study.
Srivorakul S, et al.
Vet Sci. 2025 Sep;12(9):845. PMID: 41012770 DOI: 10.3390/vetsci12090845
“A reverse-transcriptase recombinase polymerase amplification assay combined with a lateral flow dipstick (RT-RPA-LFD) was developed for point-of-care detection of Tilapia Lake Virus. The dipstick was prepared with immobilized anti-FITC and anti-biotin capture antibodies compatible with TiLV-specific primers tagged with FITC and biotin. Reverse transcription and RPA amplification were completed at 39 °C within 20 min, and products were visualized as a positive band on the LFD, achieving a 3.19 copies/µL limit of detection—a 100-fold improvement over RT-PCR-LFD.”

4.Identification, sorting and profiling of functional killer cells via the capture of fluorescent target-cell lysate.
Luah YH, et al.
Nat Biomed Eng. 2024 Mar;8(3):248–262. PMID: 37652987 DOI: 10.1038/s41551-023-01089-z
“PAINTKiller, a flow-cytometry-compatible assay for identifying and sorting functional cytotoxic effector cells in co-cultures, relies on capturing the intracellular carboxyfluorescein succinimidyl ester released from lysed target cells onto the surface of the killing lymphocyte. Capture was achieved using a bispecific complex consisting of an anti-fluorescein isothiocyanate antibody linked to an antibody against the pan-leucocyte receptor CD45, which ‘painted’ the natural killer cell surface with fluorescent lysate and enabled FACS sorting followed by single-cell RNA-seq profiling of killer-cell subpopulations.”

5.Fluorescein-switching-based lateral flow assay for the detection of microRNAs.
Ryu JY, et al.
Org Biomol Chem. 2024 Oct;22(40):8182–8188. PMID: 39291769 DOI: 10.1039/d4ob01311e
“A fluorescein-switching lateral flow assay was developed for naked-eye detection of microRNA biomarkers (miR-6090 and miR-141 for prostate cancer). Reduced fluorescein on the probe only weakly binds gold-nanoparticle-conjugated anti-fluorescein antibodies; in the presence of target microRNA, riboflavin tetraacetate photo-oxidizes the probe back to native fluorescein, which strongly binds the antibodies on the strip to produce a visible line. Sodium borohydride was introduced to minimize background, enabling fmol-level microRNA detection with minimal false positives for point-of-care cancer diagnostics.”