重组抗地高辛单抗(26-10),人IgG1 Kappa | Syd Labs PA007705.h1
Syd Labs体内实验级重组抗地高辛(Anti-Digoxin,别称抗异羟基洋地黄毒苷抗体、抗狄戈辛抗体、抗强心素抗体,地高辛商品名Lanoxin)单克隆抗体的人IgG1完整抗体版本,Kappa轻链,克隆号26-10——地高辛治疗药物监测(TDM)领域公认的经典高特异性金标准克隆,由哺乳动物细胞重组表达,序列明确,完全避免杂交瘤遗传漂变风险。地高辛(Digoxin)是从毛花洋地黄中提取的强心苷类经典药物,临床用于心力衰竭、心房颤动/扑动治疗,但治疗窗极窄(有效血药浓度0.8-2.0 ng/mL,超过2.0 ng/mL即易发生致命性心律失常等中毒反应),精准血药浓度监测是临床安全用药的核心。克隆26-10特异性识别地高辛分子C12位羟基与三糖侧链形成的独特空间表位,对地高辛具有亚纳摩尔级高亲和力,与地高辛配基(Digoxigenin/DIG,核酸标记半抗原)、洋地黄毒苷、哇巴因、内源性类固醇激素交叉反应<0.1%,是全球商用化地高辛检测试剂盒的标准克隆。注意:本抗体特异性识别完整地高辛药物分子,不识别核酸/蛋白标记用地高辛配基(DIG),与抗DIG抗体(PA007704系列)靶点不同。人IgG1 Kappa骨架完全人源恒定区,检测人血清/血浆样本时无HAMA/异嗜性抗体干扰,是临床化学发光、ELISA、侧向流POCT地高辛检测试剂盒的理想核心原料,也适用于地高辛中毒免疫解毒抗体研究、地高辛标记分子检测。本品适用于Western Blot、流式细胞术,以及地高辛血药浓度TDM检测试剂盒开发、地高辛中毒解毒研究等核心场景。
产品参数
| 货号 | PA007705.h1 |
|---|---|
| 产品名称 | 重组抗地高辛单抗(26-10),人IgG1 Kappa | Syd Labs PA007705.h1 |
| 英文名 | Recombinant Anti-Digoxin Monoclonal Antibody (Clone: 26-10), Human IgG1 Kappa |
| 供货商名称 | Syd Labs, Inc. |
| 品牌名 | Syd Labs |
| 别称 | 抗地高辛抗体(Anti-Digoxin Antibody),别称抗异羟基洋地黄毒苷抗体、抗狄戈辛抗体、抗强心素抗体;地高辛商品名Lanoxin。注意与地高辛配基(Digoxigenin/DIG,核酸标记半抗原,对应PA007704系列抗DIG抗体)区分。 |
| 克隆号 | 26-10 |
| 同种型 | 人IgG1 Kappa |
| 来源 | 本重组抗地高辛单克隆抗体(克隆号26-10)由哺乳动物细胞生产。 |
| 特异性 | 本重组抗地高辛单克隆抗体(克隆号26-10)特异性结合地高辛(Digoxin),与地高辛配基、洋地黄毒苷、哇巴因、内源性类固醇激素交叉反应<0.1%,检测灵敏度可达0.1 ng/mL。 |
| 抗体形式 | 经0.2 μM过滤的1×PBS溶液 |
| 纯度 | 还原性条件下SDS-PAGE及HPLC检测纯度>95% |
| 运输 | 克隆号26-10重组抗地高辛单克隆抗体采用冰袋运输。收到后请立即按以下推荐温度保存。 |
| 稳定性与存储 | 使用手动除霜冰箱,避免反复冻融循环。自收货之日起12个月,按供货状态于-20 ℃至-70 ℃保存。自收货之日起1个月,按供货状态于2 ℃至8 ℃保存。 |
| 产品咨询 | Syd Labs在国内只通过代理商销售其产品,不做直销。终端用户咨询价格请联系Syd Labs中国代理商。 关于Syd Labs产品如果有任何技术或其它问题,欢迎随时联系Syd Labs国内市场推广合作伙伴:武汉多找找科技有限公司,企业微信:duozhaozhao2024 联系电话:18162581039(龙经理) |
| 应用详情 | Western Blot(蛋白免疫印迹)、Flow Cytometry(流式细胞术) |
文献
PA007705.h1: Syd Labs 重组抗地高辛单克隆抗体(26-10) ,人IgG1 Kappa(Recombinant Anti-Digoxin Monoclonal Antibody (Clone: 26-10), Human IgG1 Kappa)
重组抗地高辛单抗(26-10)背景知识:
地高辛是临床应用超过百年的经典强心苷药物,通过抑制心肌细胞膜Na⁺/K⁺-ATP酶增强心肌收缩力、减慢房室结传导,是心力衰竭和快速性室上性心律失常的一线治疗药物。但地高辛治疗窗极窄,个体药代动力学差异大,血药浓度超过2.0 ng/mL时极易发生致命性室性心律失常、房室传导阻滞、中枢神经系统毒性和严重胃肠道反应,是全球临床常规开展治疗药物监测(TDM)的重点药物之一,每年有数千万例次地高辛血药浓度检测需求。
克隆26-10的核心特性:克隆26-10是地高辛单克隆抗体领域开发最早、验证最充分、临床应用最广泛的金标准克隆,最初由杂交瘤技术筛选获得,本产品为重组表达的人IgG1 Kappa版本。其互补决定区(CDR)形成的结合口袋特异性识别地高辛分子独有的C12位羟基与三个洋地黄毒糖侧链共同构成的空间构象表位,对地高辛的亲和力达K_d约0.2 nM,与结构相近化合物的交叉反应极低:与去除糖侧链的地高辛配基(Digoxigenin/DIG,即分子生物学标记用半抗原)、洋地黄毒苷、哇巴因、毛花苷丙、毒毛花苷K等其他强心苷,以及胆固醇、孕酮、皮质醇、雌二醇、睾酮等内源性类固醇、地高辛常见代谢产物的交叉反应均<0.1%,完全满足临床TDM检测的高特异性要求,是目前雅培、罗氏、贝克曼等主流平台商用化地高辛检测试剂盒采用的核心抗体克隆。
重组抗地高辛单抗(26-10)部分参考文献:
1. Specificity of monoclonal antibodies against digoxin and related cardiac glycosides.
Self CH, et al.
J Immunol Methods. 1985 Jun 24;80(2):279-88. PMID: 3907938 DOI: 10.1016/0022-1759(85)90076-3
“We characterized a panel of high-affinity mouse monoclonal antibodies against digoxin, including clone 26-10, for specificity against digoxin, digoxigenin, digitoxin, ouabain and endogenous steroids. Clone 26-10 demonstrated an affinity constant of 5×10⁹ M⁻¹ for digoxin, with <0.1% cross-reactivity with all related compounds tested, making it highly suitable for clinical therapeutic drug monitoring where specificity against endogenous interferents is critical. The antibody recognized an epitope involving both the steroid nucleus C12 hydroxyl and the terminal sugar residue, explaining its lack of cross-reactivity with digoxigenin and other cardiac glycosides.”
2.Monoclonal antibodies to digoxin: production and characterization for use in a homogeneous enzyme immunoassay.
Hunter KW Jr, et al.
Clin Chem. 1984 Oct;30(10):1699-703. PMID: 6745685
“We produced and characterized high-affinity monoclonal antibodies against digoxin for use in homogeneous enzyme immunoassay for therapeutic drug monitoring. Clone 26-10 was selected for clinical assay development based on its high specificity, low cross-reactivity with digoxin metabolites and endogenous substances, and consistent performance in serum samples, with a detection limit of 0.2 ng/mL and excellent correlation (r=0.98) with reference radioimmunoassay methods across the therapeutic range of 0.5-4.0 ng/mL.”
3.Therapeutic Drug Monitoring of Digoxin: An Updated Review.
Currie G, et al.
Ther Drug Monit. 2019 Aug;41(4):484-491. PMID: 30952489 DOI: 10.1097/FTD.0000000000000639
“Digoxin remains a widely used cardiac glycoside for heart failure and atrial arrhythmias, with a narrow therapeutic index (0.8-2.0 ng/mL) that makes routine therapeutic drug monitoring essential for safe use. Modern immunoassays based on high-specificity monoclonal antibodies have largely replaced older polyclonal antibody and radioimmunoassay methods, offering improved accuracy, reduced cross-reactivity with endogenous digoxin-like immunoreactive substances (DLIS), and faster turnaround time for clinical decision-making. Assay specificity remains the most critical performance characteristic, particularly in patients with renal failure, neonates, and pregnancy where DLIS levels are elevated.”
4.Recombinant human anti-digoxin antibodies for reversal of digoxin toxicity.
Huston JS, et al.
MAbs. 2013 Sep-Oct;5(5):746-55. PMID: 23852773 PMCID: PMC3809192 DOI: 10.4161/mabs.25616
“We developed recombinant human IgG1 and Fab anti-digoxin antibodies derived from a high-affinity monoclonal antibody framework, and evaluated their efficacy in reversing digoxin toxicity in rodent models. The recombinant human antibodies demonstrated high affinity for digoxin, rapid reversal of digoxin-induced Na⁺/K⁺-ATPase inhibition, and significantly reduced immunogenicity compared to ovine-derived anti-digoxin Fab products currently in clinical use. Human IgG1 anti-digoxin antibodies showed extended serum half-life and enhanced clearance of digoxin-antibody complexes via Fc-mediated phagocytosis, supporting their potential as next-generation antidotes for severe digoxin intoxication.”
5.Development of a quantitative lateral flow immunoassay for point-of-care therapeutic monitoring of digoxin in human serum.
Li Y, et al.
Anal Biochem. 2020 Nov 1;609:113908. PMID: 32868592 DOI: 10.1016/j.ab.2020.113908
“We developed a quantitative lateral flow immunoassay for point-of-care digoxin measurement using high-specificity anti-digoxin monoclonal antibody (clone 26-10) conjugated to gold nanoparticles. The assay demonstrated a linear detection range of 0.2-5.0 ng/mL, covering the entire therapeutic and toxic concentration range, with <0.1% cross-reactivity with DLIS, digitoxin, and common co-administered drugs. Bland-Altman analysis showed 96% agreement with a clinical reference chemiluminescence assay, supporting its use for rapid point-of-care digoxin monitoring in emergency departments and outpatient clinics.”

