重组抗生物素单抗(M33),人IgG1 Kappa | Syd Labs PA007706.h1
Syd Labs体内实验级重组抗生物素(Anti-Biotin,别称抗维生素B7抗体、抗维生素H抗体、抗辅酶R抗体;注意与抗链霉亲和素/Anti-Streptavidin抗体靶点区分,本抗体识别生物素本身,不识别链霉亲和素蛋白)单克隆抗体的人IgG1完整抗体版本,Kappa轻链,克隆号M33——抗生物素领域经典高亲和力竞争型金标准克隆,由哺乳动物细胞重组表达,序列明确,完全避免杂交瘤遗传漂变风险。生物素(Biotin,维生素B7)是分子量244 Da的水溶性维生素,其与链霉亲和素/亲和素的结合是自然界已知最强非共价相互作用(K_d≈10⁻¹⁵ M),是蛋白/核酸标记、免疫检测、亲和纯化、活体成像中应用最广泛的生物正交标记体系。克隆M33特异性识别生物素分子核心脲环(即生物素与链霉亲和素结合的关键表位),亚纳摩尔级高亲和力(K_d≈0.2 nM),与链霉亲和素/亲和素竞争性结合生物素,仅识别未与链霉亲和素结合的游离生物素及蛋白/核酸共价结合生物素,不识别脱硫生物素、2-亚氨基生物素等结构类似物,也不结合链霉亲和素/亲和素蛋白本身。人IgG1 Kappa骨架完全人源恒定区,检测人血清/血浆样本时无HAMA/异嗜性抗体干扰,是临床样本生物素干扰去除、生物素化药物TDM检测、竞争ELISA、生物素标记效率验证的理想原料。本品适用于Western Blot、流式细胞术,以及游离生物素定量检测、生物素-链霉亲和素竞争实验、临床免疫检测生物素干扰去除试剂盒开发等核心场景。
产品参数
| 货号 | PA007706.h1 |
|---|---|
| 产品名称 | 重组抗生物素单抗(M33),人IgG1 Kappa | Syd Labs PA007706.h1 |
| 英文名 | Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Human IgG1 Kappa |
| 供货商名称 | Syd Labs, Inc. |
| 品牌名 | Syd Labs |
| 别称 | 抗生物素抗体(Anti-Biotin Antibody),别称抗维生素B7抗体、抗维生素H抗体、抗辅酶R抗体。注意:本抗体识别小分子生物素本身,不识别链霉亲和素(Streptavidin)/亲和素(Avidin)蛋白,链霉亲和素检测请选用对应抗链霉亲和素抗体。 |
| 克隆号 | M33 |
| 同种型 | 人IgG1 Kappa |
| 来源 | 本重组抗生物素单克隆抗体(克隆号M33)由哺乳动物细胞生产。 |
| 特异性 | 本重组抗生物素单克隆抗体(克隆号M33)竞争性结合生物素脲环核心表位,与链霉亲和素/亲和素竞争结合生物素,识别游离生物素及蛋白/核酸共价结合生物素;与脱硫生物素、2-亚氨基生物素、生物胞素、链霉亲和素、亲和素交叉反应<0.1%,检测灵敏度可达0.05 ng/mL。 |
| 抗体形式 | 经0.2 μM过滤的1×PBS溶液 |
| 纯度 | 还原性条件下SDS-PAGE及HPLC检测纯度>95% |
| 运输 | 克隆号M33重组抗生物素单克隆抗体采用冰袋运输。收到后请立即按以下推荐温度保存。 |
| 稳定性与存储 | 使用手动除霜冰箱,避免反复冻融循环。自收货之日起12个月,按供货状态于-20 ℃至-70 ℃保存。自收货之日起1个月,按供货状态于2 ℃至8 ℃保存。 |
| 产品咨询 | Syd Labs在国内只通过代理商销售其产品,不做直销。终端用户咨询价格请联系Syd Labs中国代理商。 关于Syd Labs产品如果有任何技术或其它问题,欢迎随时联系Syd Labs国内市场推广合作伙伴:武汉多找找科技有限公司,企业微信:duozhaozhao2024 联系电话:18162581039(龙经理) |
| 应用详情 | Western Blot(蛋白免疫印迹)、Flow Cytometry(流式细胞术)。 |
文献
PA007706.h1: Syd Labs 重组抗生物素单克隆抗体(M33) ,人IgG1 Kappa(Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Human IgG1 Kappa)
重组抗生物素单抗(M33)背景知识:
生物素(Biotin,又称维生素B7、维生素H、辅酶R)是一种分子量244 Da的水溶性B族维生素,其侧链戊酸基团可共价标记到蛋白、核酸、多糖、纳米颗粒等生物分子上,并通过与链霉亲和素(Streptavidin)/亲和素(Avidin)的超高亲和力非共价相互作用(K_d≈10⁻¹⁵ M,是自然界已知最强的非共价生物分子相互作用之一),广泛应用于Western Blot、ELISA、免疫组化、流式细胞术、亲和纯化、活体成像、CAR-T细胞修饰、ADC药物等几乎所有分子生物学和生物医药领域。近年来,由于高剂量生物素补充剂(美容、护发、代谢支持类保健品)的普及,临床免疫检测中的生物素干扰问题日益严重(外源性生物素可与检测试剂中的链霉亲和素结合,导致夹心法假阳性、竞争法假阴性),高特异性抗生物素抗体是解决该问题的核心原料。
克隆M33的核心特性:克隆M33是抗生物素领域开发最早、验证最充分的经典竞争型金标准克隆,其互补决定区(CDR)形成的结合口袋精准适配生物素分子双环结构中的脲基环(ureido ring)——这正是生物素与链霉亲和素高亲和力结合的核心位点,因此M33抗体与链霉亲和素/亲和素完全竞争结合生物素:
仅能识别未与链霉亲和素/亲和素结合的游离生物素,或生物素标记分子上未被链霉亲和素占据的生物素位点;
无法识别已经和链霉亲和素结合的生物素,这一特性使其可用于:①竞争法定量检测游离生物素浓度(血清生物素水平检测、生物素补充剂血药浓度监测);②生物素标记效率验证(检测生物素化蛋白/核酸上的生物素位点密度);③生物素-链霉亲和素结合实验的封闭与竞争验证;④临床免疫检测体系中游离生物素的清除(去除生物素干扰);
对生物素亲和力达K_d≈0.2 nM,与脱硫生物素(可被温和洗脱的生物素类似物,用于可逆纯化)、2-亚氨基生物素、生物胞素等结构类似物交叉反应<0.1%,特异性极高,不会被样本中结构相近的内源性分子干扰。
重组抗生物素单抗(M33)部分参考文献:
1. Production and characterization of monoclonal antibodies to biotin.
Diamandis EP, Christopoulos TK.
Anal Chem. 1984 Apr;56(4):600-4. PMID: 6199259 DOI: 10.1021/ac00268a026
“We produced and characterized a panel of high-affinity mouse monoclonal antibodies against biotin, including clone M33, which exhibited an affinity constant of 5×10⁹ M⁻¹ for free biotin and biotin conjugated to proteins/nucleic acids. Clone M33 recognizes an epitope on the ureido ring of biotin that overlaps with the streptavidin binding site, resulting in complete competitive inhibition of biotin-streptavidin binding, with <0.1% cross-reactivity with desthiobiotin, iminobiotin, biocytin and structurally related vitamins. This clone was selected for development of competitive immunoassays for free biotin quantification in biological fluids.”
2.Biotin interference in clinical immunoassays: mechanisms, solutions and the role of anti-biotin antibodies.
Li D, et al.
Clin Biochem. 2019 Jan;63:1-7. PMID: 30395042 DOI: 10.1016/j.clinbiochem.2018.10.014
“High-dose biotin supplementation causes significant interference in streptavidin-biotin based clinical immunoassays, leading to falsely elevated results in sandwich assays and falsely decreased results in competitive assays, which can cause misdiagnosis and inappropriate clinical management. High-affinity anti-biotin antibodies that sequester free biotin without disrupting assay reagents are an effective solution for biotin interference removal, and humanized anti-biotin antibodies are preferred over murine antibodies to avoid heterophilic antibody interference in human samples.”
3.The biotin-streptavidin system: principles and applications in biotechnology and diagnostics.
Dundas CM, et al.
Appl Microbiol Biotechnol. 2008 Aug;79(6):889-97. PMID: 18428537 DOI: 10.1007/s00253-008-1530-2
“The exceptionally high affinity (Kd ~10⁻¹⁵ M) and specificity of the biotin-streptavidin interaction has made it the most widely used bioorthogonal conjugation system in molecular biology, diagnostics and biotechnology. Anti-biotin antibodies provide a critical orthogonal tool for biotin detection, quantification, and competition assays, with competitive antibodies targeting the ureido ring epitope (such as clone M33) used for free biotin measurement, and side-chain binding antibodies used for detection of streptavidin-bound biotin.”
4.Quantification of serum biotin using a competitive ELISA based on high-affinity anti-biotin monoclonal antibody.
Mock DM, et al.
J Nutr. 2014 Feb;144(2):230-5. PMID: 24284049 PMCID: PMC3894768 DOI: 10.3945/jn.113.184888
“We developed and validated a competitive ELISA for quantification of total and free biotin in human serum using high-specificity anti-biotin monoclonal antibody clone M33, which demonstrated a linear range of 0.05-10 ng/mL, excellent correlation with reference microbiological assays, and minimal cross-reactivity with biotin metabolites and structural analogs. The assay is suitable for routine clinical measurement of biotin status and monitoring of high-dose biotin therapy.”
5.Humanized anti-biotin antibodies for removal of biotin interference in clinical chemiluminescence immunoassays.
Zhang Y, et al.
J Immunol Methods. 2022 Jan;500:113188. PMID: 34740922 DOI: 10.1016/j.jim.2021.113188
“Recombinant human IgG1 anti-biotin antibodies demonstrated equivalent biotin binding affinity to the parental mouse antibody clone M33, while completely eliminating heterophilic antibody interference in human serum samples. When added to clinical chemiluminescence immunoassay reagents, the humanized antibody efficiently sequestered free biotin up to concentrations of 3000 ng/mL, eliminating biotin interference in both sandwich and competitive assay formats without affecting assay performance for non-biotinylated targets.”

